Study of voltage harmonic contamination in the (MV) cables with metallic screen of multipoint earth and sheath voltage limiter in the micro grid networks
نویسندگان :
Javad Behkesh noshahr
1
1- شرکت توزیع نیروی برق اردبیل
کلمات کلیدی :
Harmonic contamination،Metallic screen،Eddy current،harmonic emission،renewable sources of energy
چکیده :
In recent years, with the growth of using renewable energy sources and their connection to the network, some unexpected problems in electrical equipment are observed. By integrating renewable energy sources with the ability to produce megawatts and two-way electrizing the cables, we observe the complexity of utilization issues, damage and cable failure arising from harmonic contamination. Renewable energy sources, due to the use of power electronics equipment’s and static converters with high switching frequency in their manufacturing technology, are a potential source of voltage and current harmonic contamination. Generally, in the medium voltage cables to reduce and remove electric field, the metallic screen method with single-point, double-point, multipoint earth with the sheath voltage limiter or cross bonding is used. However, use of multipoint method earth method with sheath voltage limiter is more efficient than the other methods and reduces the rate of losses in the metallic screen and the number of eddy current loops in the metallic screen circuit, but this method results in increase of harmonic emission in the main conductor voltage of cable. By integrating renewable sources of energy and changing the operating conditions, especially the two-way electrizing of equipment’s and increase of the harmonious contamination arising from connection of such resources in micro grids, it is necessary to evaluate the effects of such resources on the performance of sensitive network equipment’s such as cables and shields. In this article it has been attempted, first, the matrix parameters of RLC of three-phase cable (monopole) are calculated according the conduction and insulation features. Then the rate of increase of voltage harmonic contamination in the main conductor of cable is examined by multipoint earthing method and sheath voltage limiter with presence of renewable sources of energy. Also the rate of annual energy losses in the metallic screen is calculated by the two techniques of multipoint earthing equipped to sheath voltage limiter and cross bonding is calculated and compared. Results show that in the multipoint method with sheath voltage limiter the rate of voltage harmonic contamination has increased 55%in the cable main conductor. While, the rate of losses energy in the metallic screen has reduced 71% compared to the cross bonding method. It is necessary to mention that in both methods the amount of the induced voltage in the metallic screen of cable is within the range determined by provisions of 523-05-01. Simulation for this study has been performed in the Matlab/Simulink setting and in a real time form.
لیست مقالات
لیست مقالات بایگانی شده
Price Bidding in Electricity Energy Exchange Market Considering Sensitivity Analysis of Consumption Factor
Ali Khatami
A Voltage/Frequency Variation-aided Load Shedding for Emergency Control of Islanded Microgrids
Mohammad Azimi - Mobin Naderi - Hassan Bevrani
شبیهسازی و تحلیل روشهای بهبود پروفیل ولتاژ در شبکه ولتاژ متوسط در بستر GIS (مطالعه موردی یک فیدر در شهرستان گنبدکاووس)
فرامرز اشجعی سنزیقی - محمد علی عرب - علیرضا خسروی - رضا شهمرادی - محسن قاسمی
بهینه سازی تعداد و مسیرهای پیمایش ماموران قرائت خوان کنتور در سطح شهر با استفاده از الگوریتم بهینه سازی بهبود یافته مبتنی بر آموزش و یادگیری
حمیدرضا مسرور - محسن باقری - مژده فخارزادگان
ارائه مدلی بومی برای انتخاب بهترین رویکردهای نگهداری و تعمیرات برای تجهیزات شبکههای توزیع
مرتضی خرّم - حامد بحرانی - رامین صاحبی
Analyzing Electricity Market Data By Method Multidimensional Data Analysis Using Power BI Software
Javad Shabbidar - Sasan Houshangifar - Sara Salehi - Mehran Nasr
پیاده سازی ارزیابی بلوغ سازمانی در ارتباط با استقرار نظام مدیریت دارائی های فیزیکی و ارائه نقشه راه با رویکرد استاندارد ISO55000 و مدل وایرمن
علیرضا علیزاده - پیام جوادی - حسام الدین یوسفیان - محمدابراهیم طیبی - محمدجعفر جعفری - مهیار نجفی نژاد
اثرات و کاربرد ترانسفورماتورهای هوشمند در شبکه های توزیع برق و نقش فناوری های جدید اطلاعاتی و ارتباطی در آن ها
حسین قاسمی - یاسر سرحدی - کامبیز ناظریان - میثم جعفرزاده
جایابی بهینه خازن در شبکه های توزیع به روش الگوریتم ژنتیک (مطالعه موردی فیدر 409 مروارید از ایستگاه فوق توزیع558 صغاد)
سعید جلیلی - مجتبی آزادی - محمود دهقان
بررسی میزان تاب آوری و توانایی بازگشت پذیری شبکه توزیع برق استان گلستان (آنتن افراتخته) و متدلوژی باز طراحی آن در مقابل حوادث طبیعی و راهکارهای بهبود آن براساس GIS ،مهندسی ارزش
علی بسطامی - محمد جواد علینژاد - ابوطالب دیلم - عمار نکاحی - روح الله میقانی نژاد
بیشتر
محل شرکت
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.9.1